Secured Trading Service

Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter

WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Order Sample

Product Highlights

  • Customizable ORP Range: ORP range can be customized to -1000~1000mV or -2000~2000mV.
  • Dual Output Modes: Supports 4-20mA and RS485 output modes for flexible integration.
  • OEM and ODM Support: Offers full OEM and ODM customization services for clients.
  • 1-Year Warranty: Comes with a 1-year warranty covering quality problems and maintenance.
  • Advanced Display: Features a 2.8-inch monochrome LCD with 128*64 resolution.
  • Multiple Certifications: Certified with CE, ISO 9001, ISO 14001, ISO 10012, and OHSAS 18001.
  • Versatile Connection: Available in Pen Type or Table Type connection modes.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter

Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter pictures & photos
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
  • Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
    Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter

Find Similar Products

Product Description

Measuring wastewater PH meter Water Quality online analyzer ORP meter

         
       Acidity meter (also known as pH meter) is an instrument used to measure the pH value of a solution, and the method for measuring the pH value of an acidity meter is a potentiometric method. In addition to measuring the acidity of the solution, it can also measure the electromotive force (mV) of the battery. It is mainly composed  parts: reference electrode(calomel electrode), indicator electrode (glass electrode) and precision potentiometer.
       When measuring, the glass electrode is used as the indicating electrode, and the saturated calomel electrod (SCE) is used as the reference electrode to form a battery.
Product Description

 

Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
 
Specification
Mode
KK-PH160
Display
2.8-inch monochrome LCD display, resolution 128*64
Dimensions
96x96x112mm
Hole Size
92x92mm
Weight
1.0kg
Measure range
pH:0.00-14.00pH
ORP:-1000~1000mV
-2000~2000mV(customized)
Accuracy
pH:±0.02pH;ORP:±lmV
Input resistance
>1012Ω
Temp.Comp
NTC10K:-10~60ºC accuracy :±0.3ºC
-10~130ºCManu/Auto
Current output
Isolated type, 4~20mA can be set to correspond to pH/ORP and temperature
Measure range
The maximum load is 750Ω, the output accuracy is ±0.2%FS
Alarm function
2 channels, capacity AC250V/3A, normally open
Relative humidity
10~85%RH(10~85%RH)
Working Temp.
0~60°ºC

Power supply
220VAC 50
24VDC
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
 
Company Profile
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Founded in 2010, WEIHAI KUNKE FLOW INSTRUMENT is a high-tech company specialize in flow instrument R&D,
production, sales and services of instruments.With advanced inspection instruments and equipment, professional talent team,
perfect scientific management control system, WEIHAI KUNKE has been distinguished as a leading role in industry.
We introduced advanced manufacturing technology from United States. We own a series of automation instruments with
independent intellectual property rights and advanced domestic automation instruments. Company has successively
obtained International Quality System Certification of ISO 9001-2015, Environmental Management System Certification
of ISO14001-2015, Measurement Management System Certification of ISO10012-2003 and OHSAS18001-2007
Occupational Health and Safety Management System Certification.
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP Metercredential
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
Packing & Delivery
Measuring Wastewater pH Meter Water Quality Online Analyzer ORP MeterMeasuring Wastewater pH Meter Water Quality Online Analyzer ORP Meter
FAQ
1. Q:Same sample, two measurements of pH value is different?
A:A change in temperature or a chemical reaction in the sample itself will cause a change in pH value. Therefore, the temperature should be kept as consistent as possible and chemical reactions should be avoided.
2. Q:Why does the same sample, measured on two pH meters at the same time, have inconsistent readings?
A:Due to the different correction conditions of the two pH meters (such as the correction done at different times), the measured values are different. Therefore, the pH meter should be corrected with the same buffer at the same time, and then measured at the same time.
3. Q:PH meter measurement is unstable and takes a long time. Why is that?
A:Because of aging electrodes. The response time of the electrode in the buffer can be tested, and if it is greater than 1 minute, the electrode needs to be activated or replaced with a new electrode. If the response time of the measurement buffer is short, but the measurement sample is unstable, it indicates that the electrode is not suitable for measuring the sample under test. Please select the appropriate electrode according to the electrode selection guide.
4 .Q:Why has the buffer deteriorated and become unusable during its validity period?
A:Buffer life refers to the shelf life of unopened use state. Once opened and used, the buffer is easy to deteriorate due to the action of various molds in the air. Note: The used buffer must not be poured back into the original bottle!
5 .Q:How often should the electrodes be calibrated?
A:The calibration frequency of the electrode depends on the specific situation of electrode use, maintenance, sample nature and measurement accuracy. Calibration is recommended once a day; No more than one calibration per week. If the electrode is replaced and not used for a long time, it must be calibrated before use.
6. Q:The sample temperature is 10ºC. Does the meter show the pH value at 10ºC or 25ºC?
A:The pH meter shows the pH of the solution at the current temperature; If measure
 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR265202". Items marked "verified" are certified.

Watch Video
Watch Video
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.

About Our Factory & Business Background

Address
No. 196, Hexing Road, Yangting Town, Huancui District, Weihai, Shandong, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CIF, DAP
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
qingdao

Our Production Capability & Technical Expertise

Main Products
Vortex Flow Meter, Liquid Turbine Flow Meter, Thermal Gas Mass Flow Meter, Electromagnetic Flowmeter, Gas Turbine Flow Meter, Roots Flow Meter, Mass Flowmeter

Our Industry Experience & Global Business Record

Export Year
2019-03-07
Main Markets
South America, Eastern Europe, Southeast Asia, Oceania, Mid East, Eastern Asia

FAQ

Why are two measurements of the same pH sample different?
A change in temperature or a chemical reaction in the sample itself will cause a change in pH value. Therefore, the temperature should be kept as consistent as possible and chemical reactions should be avoided.
Why do two pH meters show inconsistent readings for the same sample at the same time?
Due to the different correction conditions of the two pH meters (such as the correction done at different times), the measured values are different. Therefore, the pH meter should be corrected with the same buffer at the same time, and then measured at the same time.
Why is the pH meter measurement unstable and takes a long time?
Because of aging electrodes. The response time of the electrode in the buffer can be tested, and if it is greater than 1 minute, the electrode needs to be activated or replaced with a new electrode. If the response time of the measurement buffer is short, but the measurement sample is unstable, it indicates that the electrode is not suitable for measuring the sample under test. Please select the appropriate electrode according to the electrode selection guide.
Why has the buffer deteriorated and become unusable during its validity period?
Buffer life refers to the shelf life of unopened use state. Once opened and used, the buffer is easy to deteriorate due to the action of various molds in the air. Note: The used buffer must not be poured back into the original bottle!
How often should the electrodes be calibrated?
The calibration frequency of the electrode depends on the specific situation of electrode use, maintenance, sample nature and measurement accuracy. Calibration is recommended once a day; No more than one calibration per week. If the electrode is replaced and not used for a long time, it must be calibrated before use.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now