• Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
  • Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
  • Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
  • Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
  • Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
  • Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter

Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter

After-sales Service: Professional Engineer After-Sales Service
Warranty: 1 Year
Accuracy: >±1%
Samples:
US$ 2500/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter pictures & photos
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
US $1,600-1,698 / Set
Min. Order: 1 Set
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
KUA-100
Main Application
Nature Gas, Corrosive Liquid/Gas
Size
DN100-500
Sensor
Plug-in
Application
Energy Metering
Type
Ultrasonic Flow Meter
Measuring Media
Gas
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
DIN, ANS, GB, CE, RoHS, ISO
Connection Mode
Flange Connection
Measuring Medium
Gas
Pressure Rating
1.6
Service Temperature
Normal Temperature
Output Mode
4-20mA
Communication Protocol
RS485
Transport Package
Carton or Wooden Case
Specification
DN80
Trademark
kunke andao
Origin
China
HS Code
90261000
Production Capacity
10000

Packaging & Delivery

Package Size
45.00cm * 17.00cm * 19.00cm
Package Gross Weight
10.000kg

Product Description


Wide measuring range gas DN150 gas ultrasonic flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
KUA gas ultrasonic flowmeter is manufactured with advanced German technology, and its key components are imported with original packaging, which is reliable
High, stable performance, long service life, etc. It is a new type of precision measuring instrument with high precision and high reliability. Extensible,It is used for gas flow measurement in urban gas, petroleum, chemical, electric power, metallurgy and other industries.LQUA gas ultrasonic flowmeter adopts multi-channel design, which can eliminate the influence of eddy current and asymmetric flow, and multi-channel increases redundancy
Backup the sound channel to improve the reliability of the system. Comply with international standard ISO 17089, American standard A.G.A.Report No. 9 and Chinese standard GB/T 18604-2014.


 
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
 
Main features
• Made with advanced German technology
• Multi-channel measurement, eddy current and asymmetric flow detection
• Electric field and magnetic field laminated shielding, high noise resistance
• Zero drift automatic correction, accuracy not affected by environment
• Measurement accuracy level: 1.0/1.5
• Conform to international standard ISO 17089
• Conforming to US AGA Report No. 9
• Conform to Chinese standard GB/T 18604-2014
• Ultra wide measuring range: 1:700
• Ultra low "zero" starting flow
• Dual backup lithium battery power supply
• High precision temperature and pressure compensation, volume correction
• Intelligent switching of various gas conditions and standard conditions
• Large-capacity storage, which can save data for one year
• Intelligent fault detection and fault alarm
• Free of maintenance, cleaning and long service life

Applicable standards
KUA series gas ultrasonic flowmeter conforms to international standard ISO 17089, American standard A.G.A.Report No. 9 and China
Standard GB/T 18604-2014.

Measurement accuracy level
Range of measured gas flow rate: m / s m/s
The measurement accuracy class within the range is: 1.0
0.1 Maximum allowable error ± 1.0%, repeatability: ± 0.2%
Maximum allowable error: ± 2.0%, repeatability: ± 0.4%
The measurement accuracy level within the range is: 1.5
0.1 Maximum allowable error ± 1.5%, repeatability: ± 0.3%
Maximum allowable error ± 3.0%, repeatability: ± 0.6%



Explosion-proof grade
Explosion-proof grade: Ex ib B T4 Gb; Protection grade: IP65

Working power supply
Internal power supply: a set of 3.6V 35AH lithium batteries, which can display the battery capacity in real time.
Optional external power supply: 9~24VDC, ripple system automatically switches external power supply, and external power supply adopts DC-DC
Management mode. (Safety barrier shall be installed when using intrinsic safety function)


Overall power consumption
Internal power supply: the average power consumption is 1.5mW, and a group of lithium batteries can be used continuously for more than 6 years.
Optional external power supply: average power consumption 1W
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter

Model

Flow specification

Nominal diameter(mm)

Flow range    (m3/h)

Range ratio

Starting

flow     (m3/h)

Maximum pressure loss   (Kpa)

Nominal pressure    (MPa)

KKQY-25(D)

G16

25

0.5~25

50:1

0.06

0.06

1.6

KKQY-40(D)

G16

40

0.5~25

50:1

0.06

0.06

G25

0.5~40

80:1

0.05

0.08

KKQY-50(D)

G40

50

0.65~65

100:1

0.06

0.1

G65

0.65~100

160:1

0.06

0.2

KKQY-80(D)

G100

80

1.0~160

160:1

0.07

0.3

G160

2.0~250

125:1

0.10

0.3

KKQY-100(D)

G160

100

2.0~250

125:1

0.10

0.3

G250

2.5~400

160:1

0.15

0.45

G400

4.0~650

160:1

0.60

0.45

KKQY-150(D)

G400

150

4.0~650

160:1

0.70

0.5

G650

6.5~1000

160:1

0.75

0.5

KKQY-200(D)

G650

200

6.5~1000

160:1

0.90

0.7

G1000

10~1600

160:1

1.20

0.7

 

Basic parameters
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter

Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
 
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
 
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter

FAQ

1.Q:Ultrasonic flowmeter reading unstable change drastic?

A: Retrofit the flow sensor away from the source of oscillation or move it upstream of the device that is changing the flow pattern.
2.Q:Ultrasonic flowmeter reading is not accurate, the error is large?
A:Install a sensor at a place far away from the device. The upstream distance of the sensor is 30D and the downstream distance is 10D.
3.Q:Ultrasonic flowmeter sensor is good, but the flow rate is low or no flow rate because of what?
A:1 Because the paint and rust outside the pipeline have not been removed. The sensillum. 2. The pipe surface is uneven or the ultrasonic flowmeter equipment is at the welding joint. 3, the measured medium is pure or solid suspended matter is too low.
4.Q:When the control valve is somewhat closed or the flow rate drops, the reading will increase.
A: The sensor is installed too close to the flow of the control valve, and when some closed valves are closed, the practice of flowmeter measurement is to control the flow rate of the valve to improve the flow rate, and the flow rate is increased because the diameter is reduced.
5.Q:After the ultrasonic flowmeter probe is used for a period of time, there will be an irregular alarm. Especially if there are more impurities in the conveying medium, this kind of problem will be more common
A:Solution: Clean the probe regularly (once a year is recommended).
6.Q:When the ultrasonic flow meter's conveying medium contains liquid impurities such as water, the pressure tube of the flow meter is easy to produce liquid accumulation, and when the temperature is low, the pressure tube will freeze, especially in the northern winter.
A:Solution: Purge or energize pressure tube heat tracing.
7.Q:Does the instantaneous flow fluctuate greatly?The signal intensity is high and the measured flow body fluctuates greatly.
A:Solution: Adjust the position of the probe, improve the signal strength, and ensure the stability of the signal strength. If the fluid fluctuates a lot, the position is not good





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter pictures & photos
Wide Measuring Range Gas DN150 Gas Ultrasonic Flowmeter
US $1,600-1,698 / Set
Min. Order: 1 Set
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Registered Capital
37125000 RMB
Plant Area
>2000 square meters